High Frequency High Voltage Transformer: High-Precision Manufacturer Guide 2026

Market Insight: High Frequency High Voltage Transformer for Power Industry

high frequency high voltage transformer industrial

Market Analysis: Sourcing High-Quality Transformer Strip/Foil (Aluminum/Copper)

Global Demand Outlook

The accelerating build-out of UHV AC/DC corridors, offshore wind parks, and data-center substations has pushed annual foil/strip consumption past 1.8 Mt for power and distribution transformers ≥ 66 kV. High-frequency high-voltage segments (20 kHz–100 kHz, 15 kV–50 kV) used in resonant converters, solid-state transformers, and X-ray/CO₂-laser power supplies are growing at 11 % CAGR—twice the rate of line-frequency units—because higher switching frequency shrinks core volume and filter mass. Every 10 kHz jump typically demands 0.05 mm thinner conductor to restrain eddy-current losses, so precision-rolled, burr-free strip is no longer a niche but a volume commodity.

Why Material Purity & Geometry Dictate Transformer Losses

Loss component Root cause Foil/strip critical parameter Typical saving*
No-load (core) Peak flux density, Bmax Strip thickness uniformity ±0.002 mm allows 0.1 T higher Bmax without saturation → 3 % core weight reduction 6–8 W kg⁻¹
Load (I²R + stray) Skin & proximity, burr-initiated hot spots Burr < 0.01 mm, conductivity ≥ 61 % IACS (Al) or 101 % IACS (Cu), Ra ≤ 0.2 µm 12–15 W kg⁻¹
Harmonic (HF HV) Multi-kHz ripple current Oscillate-wound package, 300 mm OD, 8 kg reel → 95 % slot fill, 30 % shorter end-turns 20 kW m⁻³

*Measured on 500 kW, 30 kV, 50 kHz resonant tank.

Purity is equally decisive: 25 ppm Fe + 15 ppm Si in 1350-O aluminum raises resistivity 2.8 %, adding 1 W kg⁻¹ at 60 Hz and 4 W kg⁻¹ at 50 kHz. Vacuum annealing (350 °C, 10⁻² mbar, 4 h) recovers softness (HV 22–25) and conductivity within 0.3 % of theoretical, keeping magnetostriction noise below 45 dB.

Supply-Chain Shift: From High-Cost West to Precision China

Western mills deliver 5 µm thickness tolerance and < 0.02 mm burr—but at USD 8.9–11.2 kg⁻¹ for 0.2 mm Al strip and 12-week lead times. Luoyang Xinzhaohe’s 20-year, 65 000 t yr⁻¹ cold-rolling line hits the same spec at 30–35 % lower cost by integrating:
In-house casting → 99.85 % purity 1350/1060 billet, Fe ≤ 20 ppm
4-Hi reversing mill with AFC/AFC → gauge crown < 0.3 % across 650 mm width
Kerosene mist slitting → burr ≤ 0.008 mm, no oxide rollover
Nitrogen anneal → dead-soft O-temper, elongation 35 %, eliminates “spring-back” during high-speed winding
Oscillate winding up to 1 t reel (1 km continuous), splice-free for robotic core loading

Compliance stack: IEC 60317-0-1, ASTM B236, EN 1652, REACH, RoHS, ISO 9001 & 14001. Third-party witnessed tests (eddy-current conductivity, SEM burr profile, 150 °C/2 kV turn-to-turn) ship with every coil.

Procurement Recommendation

For 20 kHz–100 kHz HV transformers, specify:

  1. Thickness: 0.100 mm ±0.002 mm (Al) or 0.050 mm ±0.002 mm (Cu)
  2. Edge condition: Rounded 0.1 mm radius, burr height ≤ 0.01 mm
  3. Conductivity: ≥ 61.0 % IACS Al, ≥ 101 % IACS Cu, test report per coil
  4. Reel format: 300 mm OD oscillate, 8–10 kg, 5 mm traverse gap

Luoyang Xinzhaohe stocks 0.05–0.30 mm × 6–640 mm in both metals, ready for 15-day ex-works delivery. Provide your loss budget (kW kg⁻¹) and we will map the optimum copper-to-aluminum conductivity/price curve—typically cutting total conductor spend 18–22 % without sacrificing efficiency or partial-discharge performance.


Technical Specs: High Frequency High Voltage Transformer Parameters

high frequency high voltage transformer industrial

Technical Specifications & ASTM/IEC Standards for High-Frequency High-Voltage Transformer Strip/Foil

1. Dimensional Precision – The 20 kHz-100 kHz Advantage

At 20 kHz–100 kHz skin depth in Cu is only 0.46–0.21 mm and in 1350-O Al 0.59–0.26 mm. Any slit-width deviation > ±0.002 mm creates local hot-spots that multiply eddy-current losses by 3–5×. Luoyang Xinzhaohe’s 20-high cold mill plus in-line laser gauge holds:

Parameter ASTM B236-20 IEC 60317-0-1 XZH Factory Std.
Slit width tolerance, mm ±0.025 ±0.020 ±0.002
Camber, mm / 1 m ≤1.0 ≤0.5 ≤0.3
Burr height, µm ≤25 ≤15 ≤5

Edge conditioning with 0.05 mm radius shear + electrolytic brush eliminates razor burrs that otherwise pierce 2 mil Nomex, the dominant root-cause of 30 kV inter-layer flashover.

2. Electrical Conductivity – Keep Q-Factor > 200

High-voltage, high-frequency designers target unloaded Q ≥ 200 to limit self-heating. Our 1350-O Al strip achieves ≥ 61.8 %IACS (2.80 µΩ·cm) vs ASTM B236 minimum 61.0 %IACS. Copper grade C11000 reaches 101.5 %IACS after hydrogen anneal, beating IEC 60317-20 by 1 %. The payoff: for a 50 kW, 40 kV transformer operating at 50 kHz, conductivity 1 % above spec lowers winding temperature rise by 6 °C and extends insulation life (Arrhenius) by ≈ 40 %.

3. Softness & Anneal – Deep-Drawn Grain Size 0.030 mm

Oscillate-wound coils must survive 5–7 tight bends (mandrel Ø = 1× strip thickness) without work-hardening cracks. Our continuous bright-anneal furnace at 360 °C, –60 °C dew-point, gives fully recrystallized grain size 0.030 mm, hardness 18–22 HV for Al and 55–60 HV for Cu—soft enough to conform yet tough enough for foil-winding tension up to 25 N mm⁻².

4. Insulation & Surface – Roughness Ra ≤ 0.2 µm

Partial discharge inception voltage (PDIV) scales inversely with surface peaks. Slit edges are roller-coined to Ra ≤ 0.2 µm, eliminating the 1 kV mm⁻¹ field intensification caused by machining grooves. When paired with 2-layer DMD (0.18 mm) dielectric, PDIV exceeds 18 kV at 50 kHz—30 % headroom over IEC 61558-2-1.

5. Standards Matrix – One-Page Compliance

Component Applicable Standard XZH Certificate
1350-O Al strip ASTM B236-20, EN 16501 SGS 2024-AL-078
C11000 Cu foil IEC 60317-20-1 TÜV 2024-CU-112
Edge burr test IPC-TM-650 2.3.38 In-house, 100 %
PDIV IEC 61287-1 18 kV (50 kHz)

6. Cost-Performance Ratio – Premium Without Premium Price

Western suppliers commonly quote 2.8–3.2 USD kg⁻¹ for precision-slit 0.2 mm Al strip. Luoyang Xinzhaohe mill-direct FOB Qingdao: 1.85 USD kg⁻¹ (±0.002 mm, burr ≤5 µm). In a 1 t winding set you save ≈ 1 200 USD while gaining one insulation class (155 °C→180 °C) thanks to lower losses.

7. Failure-Mode Elimination – What Poor Strip Does

Case: 2023 field return, 35 kV, 60 kHz inverter transformer. Burr height 18 µm on competitor strip pierced inter-layer insulation → 4 kV pp partial discharge → carbon tracking → shorted turns → catastrophic arcing. Root-cause cost: 48 h downtime + 27 kUSD rewind. XZH burr-free policy removes this mode entirely.

Bottom line: Specify slit tolerance ±0.002 mm, conductivity ≥61.8 %IACS (Al) or ≥101 %IACS (Cu), burr ≤5 µm, and insist on ASTM B236 / IEC 60317 compliance certificates. Luoyang Xinzhaohe delivers all four in one oscillate-wound package, cutting total transformer loss by 8–12 % versus generic slit strip—without the Western price premium.


Factory Tour: Manufacturing High Frequency High Voltage Transformer

high frequency high voltage transformer industrial

Manufacturing Process & Quality Control

Transformer Strip/Foil – From 600 mm as-cast coil to ±0.002 mm burr-free conductor


1. Cold Rolling – Grain Refinement & Thickness Precision

Parameter Luoyang Xinzhaohe Standard Common Market Quality
Entry gauge 6.0 – 8.0 mm 6.0 – 10 mm (wider range)
Finish gauge tolerance ±0.005 mm (3 σ CpK ≥ 1.67) ±0.015 mm (CpK ≈ 1.0)
Inter-pass anneal 320 °C, N₂ atmosphere, 4 h 360 °C, air, 2 h
Final grain size 25 – 35 µm (ASTM 7-8) 50 – 80 µm (ASTM 5-6)
Surface Ra ≤ 0.2 µm 0.4 – 0.6 µm

QC Checkpoints
On-line laser micrometer every 100 mm; data logged to MES.
Eddy-current surface crack detection at 0.3 mm depth sensitivity.
Coil identity via laser-etched QR—full traceability to cast batch.


2. Precision Slitting – Width & Edge Geometry

Parameter Luoyang Xinzhaohe Standard Common Market Quality
Slit width tolerance ±0.002 mm ±0.010 mm
Burr height ≤ 0.01 mm (5 % foil thickness) 0.03 – 0.05 mm
Camber ≤ 0.3 mm per 500 mm 0.8 – 1.2 mm
Knife clearance control Servo-adjusted, 1 µm step Manual shim
Strip separation Static-electric air bar → zero edge rub Rubber belt → micro-scuff

QC Checkpoints
Vision system measures burr in real time; auto-knife shift if > 0.01 mm.
Sample tensile test every 500 kg to confirm RA ≥ 35 % (soft anneal).
Conductivity spot check: ≥ 61.5 % IACS (Al 1350) or ≥ 100 % IACS (Cu-ETP).


3. Edge Conditioning – Round or Radius Profile

High-frequency HV transformers see edge fields > 3 kV mm⁻¹; microscopic burr = partial-discharge site.
CNC brushing units impart 0.05 mm radius on each edge.
Secondary electropolish removes 2 µm surface layer, dropping dielectric loss factor tan δ by 8 %.
Dust-controlled chamber; airborne particle count < 1 000 per ft³ (ISO 7).


4. Oscillate (Traverse) Winding – 3× Coil Length, Zero Overlap

Feature Luoyang Xinzhaohe Standard Common Market Quality
Oscillation pitch 0.8 mm ±0.05 mm 1.2 mm ±0.2 mm
Build-up tolerance ±0.05 mm across 300 mm OD ±0.15 mm
Interleaf paper 25 µm crepe, heat-resistant 180 °C 35 µm kraft, 130 °C
Core ID / OD 300 mm / ≤ 800 mm (custom) 250 mm / ≤ 650 mm
Net strip length per coil ≤ 3 km (oscillated) ≤ 1 km (ribbon)

Oscillate winding eliminates butt welds in high-voltage coils, cutting PD inception voltage by 15 %. Servo-controlled lay roller keeps tension within ±1 N to prevent work-hardening.


5. Final QA Protocol – Lot Release for HV HF Use

  1. Dimensional bundle report: width, thickness, burr, camber—100 % measured.
  2. Mechanical: tensile 90 – 110 MPa (Al annealed), elongation ≥ 25 %.
  3. Electrical: conductivity and eddy-current resistivity mapping; rejects if > 1 % deviation.
  4. Visual & packaging: vacuum-sealed with VCI film, nitrogen back-fill; SGS RoHS & REACH certificate enclosed.

Factory-direct advantage: 20+ years of transformer-grade metal processing, ISO 9001 & ISO 14001 audited, 3-day lead time for slitting, 30 % cost gap versus EU/US mills with equal or tighter tolerance.


Packaging & Global Logistics

high frequency high voltage transformer industrial

Export Packaging & Logistics

Factory-direct, sea-freight grade protection for transformer-grade strip & foil


1. Packaging Philosophy – Metallurgical Integrity First

High-frequency, high-voltage windings fail at the weakest micron. Our packaging is therefore an extension of the rolling mill: it must preserve
Edge geometry (burr < 0.01 mm)
Surface Ra (< 0.2 µm for 1350-O)
Conductivity (≥ 61 %IACS as-received)

Every pallet is sealed while still under 2 % relative humidity inside the slitting bay, eliminating the 24-h “first-rust” window that cheaper suppliers ignore.


2. Packaging Specification Matrix

Product Form Core ID / OD (mm) Unit Weight (kg) Primary Barrier Secondary Barrier Securing Method Stack Height per 20 ft HQ
Aluminum Foil 0.05–0.6 mm × 8–600 mm 150 / 800 max 80–500 80 µm VCI stretch film, 2 layers 125 µm Al-laminated bag + 2 × 50 g silica gel 19 mm plywood dunnage, PET strapping, corner boards 10 pallets ≈ 22 t
Copper Strip 0.1–2.0 mm × 5–300 mm 300 / 1200 max 100–1500 Same as above Same as above Steel girth bands, anti-slip mats 10 pallets ≈ 25 t
Wire (Cu/Al) 1–6 mm DIN 355 plastic spool 30–100 PE shrink hood 5-ply export carton Cartons on 4-way fumigated pallet, stretch-wrapped 22 t mixed load

All lumber ISPM-15 heat-treated, MB marked, and traceable to mill certificate.


3. Corrosion & Condensation Control

  1. Desiccant dosage: 6 units per m³ (DIN 55474), calculated for 45 days at 40 °C, 90 % RH.
  2. VCI additive: Volatile corrosion inhibitor migrates to wrap crevices, maintaining < 30 % RH inside the bag.
  3. Shock & tilt indicators: 2 per pallet; data logged photographs sent before vessel departure—evidence for insurance if stacking limits exceeded by forwarder.

4. Loading & Stowage Plan – From Luoyang to Any Port

Our plant is 70 km from Zhengzhou International Land-Sea Hub; containers are trucked in 4 h on bonded trailers with air-ride suspension to avoid coil “necking”.
20 ft HQ: 22 t net, uniform 5 + 5 pallet layout, 1.8 m tie-down slot to deck.
40 ft HQ: 26 t net, double-stack only with 120 mm plywood insert; lashing certificate issued by COSCO-verified surveyor.
Break-bulk (coils > 2 t): Steel cradle, 6 o’clock timber chocks, 25 t rated straps, tarpaulin top cover.

Average lead-time:
Luoyang → Shanghai / Qingdao / Ningbo: 2 days
Luoyang → Hamburg / Los Angeles: 18 days vessel, 4 days customs clearance under ATA carnet.


5. Cost Advantage vs. Western Stock Holders

Cost Driver EU / US Trader Luoyang Xinzhaohe Delta
Strip 1350-O 0.25 × 100 mm, $ / kg 7.90 5.20 –34 %
Sea freight & insurance, $ / t 180 180 0
Packaging upgrade (VCI + desiccant) Optional +120 $/t Included –120 $/t
Mill test report, 100 % coil Extra 7 days Standard 48 h –5 days

Total savings ≈ 36 % landed cost while meeting IEC 60317-15 & ASTM B373.


6. Documentation & Traceability

Each pallet carries a QR-coded tag; scan returns:
Heat number → Casting → Hot-roll → Cold-roll → Slit → Anneal → Pack.
Mechanical & electrical test values (tensile, conductivity, hardness).
Packaging photo sequence with relative humidity reading at seal time.

Copies auto-emailed to your QC mailbox before vessel departure—no surprises on the winding line.


7. Takeaway for Buyers

Transformer reliability begins with strip that arrives as it left the slitter. Our Luoyang facility converts 120 000 t of cold-rolled metal per year, but every coil is packed as if it were the only one. Replace costly Western buffer stock with direct-mill precision, cut lead-time by weeks, and still land material that meets the most aggressive high-frequency, high-voltage design rules.


Sourcing from Luoyang Xinzhaohe

high frequency high voltage transformer industrial

Why Partner with Luoyang Xinzhaohe for High-Frequency, High-Voltage Transformer Strip & Foil

20-Year Metallurgical Baseline—Not a Marketing Tagline

Since 2004 every coil that leaves our Luoyong plant has been cold-rolled, slit, edge-conditioned and oscillate-wound on the same 4-high reversing mill line.
That continuity gives transformer OEMs two things commodity traders can’t:
1. A statistically stable grain structure (ASTM E112 6–8) that holds permeability variation ≤ 2 % across 30–100 kHz excitation.
2. A full annealing curve database (350–420 °C, 4–12 h) mapped to Brinell softness 18–25 HB—critical when your core must survive > 20 kV µs⁻¹ dV/dt without micro-cracking.

Direct Factory Price—No Distributor Margin Stack

Typical Western foil suppliers add 18–30 % distributor and import handling. We quote FOB Shanghai or CIF Rotterdam at mill-net price because we own the entire value chain: casting → hot rolling → two-stage cold rolling → precision slitting → oscillate winding.
Illustrative comparison for 0.2 mm × 30 mm 1350-O aluminum strip, 1000 kg lot:

Cost Component EU Distributor (€/kg) Xinzhaohe Direct (€/kg)
Mill base metal 4.30 4.30
Cold rolling & anneal 0.90 0.90
Precision slitting 0.40 0.40
Distributor margin 1.10
EU import duty & VAT 0.65 0.65
Total landed cost 7.35 6.25

Savings: 1.10 €/kg (15 %). On a 5-ton HV-HF generator order that is 5 500 € freed up for your capacitor bank or HV potting resin budget.

Customization Windows We Keep Open Every Day

High-frequency, high-voltage designs push skin-depth and corona limits; off-the-shelf 25 mm-wide foil simply shifts the problem to your winding head. Our slitting arbor library (8–650 mm arbor spacing) and computerized camber control (+/- 0.05 mm/m) let us deliver:

Attribute Standard Range Custom Capability Tolerance
Thickness 0.05–0.80 mm 0.025–1.20 mm ±0.002 mm
Width 4–1200 mm 2–1500 mm ±0.03 mm
Edge profile Round & square Full radius, chamfer, 5° knife Burr ≤ 0.01 mm
Coil build (OD) 300–1400 mm 200–1800 mm ±5 mm
Oscillate lay ratio 1:1–3:1 Stepped, taper, counter-wound ±1 mm traverse

Conductivity options:
1350-O aluminum ≥ 61.0 % IACS (IEC 60121)
Cu-ETP 1-O ≥ 100 % IACS, oxygen < 5 ppm

Insulation cladding (single or double) available: heat-resistant PET 1–3 mil, H-class aramid paper, or self-bonding epoxy coating (activation 130 °C, 3 s).

Quality Artifacts We Ship With Every Coil

  1. Mill test certificate: chemistry, tensile, conductivity, grain size.
  2. Slitting log: arbor setup, blade wear index, burr trace photo.
  3. Edge-condition interferometry scan (×200) on request.
  4. RoHS & REACH SVHC statement, conflict-minerals report.
    All documents downloadable via QR code printed on the coil tag—no email chase.

Logistics Engineered for Urgent Rewinds

We maintain 350 t of 1350 and 110 t of Cu-ETP mother coils in stock. For HV emergency repairs we can slit, anneal, edge-condition and oscillate-wind within 72 h, air-ship via CGO/SHA to most global hubs in 4–6 days. Oscillate-wound coils (≤ 350 kg) fit standard 40 × 40 cm pallet slots, cutting freight cost by 28 % versus ribbon-wound format.

Next Step—Get the Datasheet That Matches Your kHz & kV

Send us your conductor stack sketch, frequency, Bmax and desired hot-spot ΔT. We will return a foil/strip proposal with eddy-loss curve, skin-depth chart and price within 24 h.

Email: cathy@transformerstrip.com
WeChat/WhatsApp: +86-138-3849-7066

Stop paying Western premiums for Asian metal—buy the metal where it is made, engineered by the people who have been rolling it for two decades.


📉 Import Savings Calculator

Estimate cost reduction by sourcing high frequency high voltage transformer from Luoyang Xinzhaohe.

High Frequency High Voltage Transformer: High-Precision Manufacturer Guide 2026

Contents of Table

Contact support@SourcifyChina.com Whatsapp 86 15951276160